Schindler 330A Low-Rise Hydraulic Elevator

Pick the elevator specifications and dimensions that meet your needs

Select the elevator dimensions and features from the fields below and Schindler Plan will configure a Model 330A hydraulic elevator that fulfills your requirements. It’s easy and only takes a few minutes. For an in-depth analysis, choose “Let’s keep going” for detailed elevator specifications, drawings. Need BIM now? Click Here. Will provide an all in one product family BIM file and BIM configuration instructional file. Once downloaded, please configure the BIM file for you specific project requirements.

Individual Hoistway Dimensions box-sizeHoistway Dimensions are determined by these four factors: A. Hoistway Width B. Hoistway Depth C. Pit Depth D. Overhead

Individual Hoistway DimensionsX

box-sizeHoistway Dimensions are determined by these four factors: A. Hoistway Width B. Hoistway Depth C. Pit Depth D. Overhead

Hoistway Width

Must select service type to view

Hoistway Depth

Must select service type and capacity to view

Pit Depth

Must select service type and capacity to view

Overhead

Must select speed to view

Plan View

Plan ViewX

Must select quantity of units, door type, door hand, and rear openings to view preview

Detailed Plan View

Detailed Plan ViewX

Must select service type, door type, jack type and rear openings to view preview

Section View

Section ViewX

Must select rear openings to view preview

Detailed Section View

Detailed Section ViewX

Must select service type, door type, jack type and rear openings to view preview

Print this Page


Basic Design Development

Quantity of Units The number of units in the elevator bank.

Quantity of UnitsX

The number of units in the elevator bank.

Service Type General Purpose: doors are always on the long side of the hoistway and ADA compliant to carry passengers. Hospital/Service: doors are on the short side of the hoistway to accommodate hospital stretcher/beds.

Service TypeX

General Purpose: doors are always on the long side of the hoistway and ADA compliant to carry passengers. Hospital/Service: doors are on the short side of the hoistway to accommodate hospital stretcher/beds.

Capacity The amount of weight an elevator can safely carry.

CapacityX

The amount of weight an elevator can safely carry.

Speed The top speed the elevator can achieve in feet per minute.

SpeedX

The top speed the elevator can achieve in feet per minute.

Door Type The number of door panels and the way they open.

Door TypeX

The number of door panels and the way they open.

Cab Height The dimension from the finished floor to the canopy of the cab.

Cab HeightX

The dimension from the finished floor to the canopy of the cab.

Door Hand The direction that the door opens when looking out from inside the elevator.

Door HandX

The direction that the door opens when looking out from inside the elevator.

Jack Type Will it be a holeless application or holed and will the jack be on the side or in the front.

Jack TypeX

Will it be a holeless application or holed and will the jack be on the side or in the front.

Rear Openings A second opening for the elevator cab.

Rear OpeningsX

A second opening for the elevator cab.

Working Drawings

Quantity of Landings On how many floors will the elevator stop.

Quantity of LandingsX

On how many floors will the elevator stop.

Quantity of Front Openings The necessary number of front openings for your elevator.

Quantity of Front OpeningsX

The necessary number of front openings for your elevator.

Quantity of Rear Openings The necessary number of rear openings required for your building.

Quantity of Rear OpeningsX

The necessary number of rear openings required for your building.

Hoistway Entrance Dimensions The width and height of the entrance that are available for the service type and capacity selected. Entrance height must be at least one foot less than the cab height.

Hoistway Entrance DimensionsX

The width and height of the entrance that are available for the service type and capacity selected. Entrance height must be at least one foot less than the cab height.

Travel Limits The distance that the elevator travels from the bottom landing to the top most landing served. (Minimum Travel Limits is 8' 6", Maximum Travel Limits is 50' 0")

Travel LimitsX

The distance that the elevator travels from the bottom landing to the top most landing served.

Machine Room Where the machine room in your building needs to be located.

Machine RoomX

Where the machine room in your building needs to be located.

Distance If your machine room is remote, how far from the elevator will your machine room be? For the 330A it must be between 10 - 100 feet away. To calculate this distance take into account the actual run length of the hydraulic piping in linear feet between the hoistway and machine room. (Minimum Distance is 0, Maximum Distance is 0)

DistanceX

If your machine room is remote, how far from the elevator will your machine room be? For the 330A it must be between 10 - 100 feet away. To calculate this distance take into account the actual run length of the hydraulic piping in linear feet between the hoistway and machine room.
Based on your machine room selection, this option is not available.

Power Supply The voltage that will be available to power the elevator.

Power SupplyX

The voltage that will be available to power the elevator.

Cab Inside Dimensions Clear cab inside width, depth, and height dimensions.

Cab Inside DimensionsX

Clear cab inside width, depth, and height dimensions.

Cab Details

Decorative Panel Type Decorative panels are a raised panel hung on to the cab walls and can be faced on both sides with laminate, stainless steel, and bronze.

Decorative Panel TypeX

Decorative panels are a raised panel hung on to the cab walls and can be faced on both sides with laminate, stainless steel, and bronze.

Cab Walls Solid walls of 16 gauge formed steel, with a painted or stainless steel finish.

Cab WallsX

Solid walls of 16 gauge formed steel, with a painted or stainless steel finish.

Cab Lighting Lights within the cab ceiling.

Cab LightingX

Lights within the cab ceiling.

Base, Frieze & Reveals Visible area surrounding the panels (base is below, frieze is above, reveals are in between).

Base, Frieze & RevealsX

Visible area surrounding the panels (base is below, frieze is above, reveals are in between).

Cab Ceiling Decorative and visible part of the top of the elevator.

Cab CeilingX

Decorative and visible part of the top of the elevator.

Cab Return & Transom The return is panel that houses the Cab Operating Panel(s). The transom is the panel above the doors and the returns.

Cab Return & TransomX

The return is panel that houses the Cab Operating Panel(s). The transom is the panel above the doors and the returns.

Cab Doors The doors that move with the cab.

Cab DoorsX

The doors that move with the cab.

Cab Handrail Mounting Mounting indicates the location and quantity of handrails in the cab.

Cab Handrail MountingX

Mounting indicates the location and quantity of handrails in the cab.

Cab Handrail Type and Finish Defines the shape and the architectural finish of the handrails inside the cab.

Cab Handrail Type and FinishX

Defines the shape and the architectural finish of the handrails inside the cab.

Cab Threshold The threshold or sill is part of the platform underneath the elevator cab.

Cab ThresholdX

The threshold or sill is part of the platform underneath the elevator cab.

Auxiliary Cab Panel Secondary car operating panel in the cab.

Auxiliary Cab PanelX

Secondary car operating panel in the cab.

Vandal Resistant Fixtures - Cab Stainless steel push buttons and lanterns in the cab.

Vandal Resistant Fixtures - CabX

Stainless steel push buttons and lanterns in the cab.

Frames, Fixtures and Finishes

Vandal Resistant Fixtures - Hall Stainless steel push buttons and lanterns in the hallway.

Vandal Resistant Fixtures - HallX

Stainless steel push buttons and lanterns in the hallway.

Frame Finishes - All Floors This means you have the same finish on all of your entrance frames at each floor.

Frame Finishes - All FloorsX

This means you have the same finish on all of your entrance frames at each floor.

Frame Finishes - 1st Floor Hoistway entrance frame at just the first floor.

Frame Finishes - 1st FloorX

Hoistway entrance frame at just the first floor.

Frame Finishes - 2nd Floor Hoistway entrance frame at just the second floor.

Frame Finishes - 2nd FloorX

Hoistway entrance frame at just the second floor.

Frame Finishes - Typical Floors Hoistway entrance frame at all other floors.

Frame Finishes - Typical FloorsX

Hoistway entrance frame at all other floors.

Door Finishes - All Floors All of the hoistway doors will have the same finish at each floor.

Door Finishes - All FloorsX

All of the hoistway doors will have the same finish at each floor.

Door Finishes - 1st Floor Hoistway door at just the first floor.

Door Finishes - 1st FloorX

Hoistway door at just the first floor.

Door Finishes - 2nd Floor Hoistway door at just the second floor.

Door Finishes - 2nd FloorX

Hoistway door at just the second floor.

Door Finishes - Typical Floors Hoistway doors at all other floors.

Door Finishes - Typical FloorsX

Hoistway doors at all other floors.

Threshold Finishes - All Floors All of the hoistways sills (part of the hoistway) will have the same finish at each floor.

Threshold Finishes - All FloorsX

All of the hoistways sills (part of the hoistway) will have the same finish at each floor.

Threshold Finishes - 1st Floor Hoistway sill at just the first floor.

Threshold Finishes - 1st FloorX

Hoistway sill at just the first floor.

Threshold Finishes - 2nd Floor Hoistway sill at just the second floor.

Threshold Finishes - 2nd FloorX

Hoistway sill at just the second floor.

Threshold Finishes - Typical Floors Hoistway sill at all other floors.

Threshold Finishes - Typical FloorsX

Hoistway sill at all other floors.

Hall Fixtures Finishes These are the hall fixture cover plates located in the hallway.

Hall Fixtures FinishesX

These are the hall fixture cover plates located in the hallway.

Maintenance Options

Regular Maintenance Standard service that is performed during regular business hours.

Regular MaintenanceX

Standard service that is performed during regular business hours.

Callback Service Emergency shutdown service that is performed 24/7.

Callback ServiceX

Emergency shutdown service that is performed 24/7.

Maintenance Period The duration in months of the initial after construction service period.

Maintenance PeriodX

The duration in months of the initial after construction service period.

Additional Options

Schindler SafeCall – Emergency wireless elevator phone line Schindler SafeCall's emergency elevator phone line service can provide potential cost savings when switching from analog to wireless phone line. It complies with local regulations ensuring regular line tests, self-checks, emergency electrical power supply. Learn More About Schindler SafeCall.

Schindler SafeCall – Emergency wireless elevator phone lineX

Schindler SafeCall's emergency elevator phone line service can provide potential cost savings when switching from analog to wireless phone line. It complies with local regulations ensuring regular line tests, self-checks, emergency electrical power supply. Learn More About Schindler SafeCall.

Two-way communication The Schindler hydro, 330A, solution utilizes an integrated COP solution, that when paired with Schindler’s optional Safe Call (analog phone line via wireless) provides a comprehensive solution to all your emergency communication services. Enhancing safety and convenience by providing passengers with multiple emergency communication options, including voice, text, and one-way video capability, visually confirming cab interior status.

Two-way communicationX

The Schindler hydro, 330A, solution utilizes an integrated COP solution, that when paired with Schindler’s optional Safe Call (analog phone line via wireless) provides a comprehensive solution to all your emergency communication services. Enhancing safety and convenience by providing passengers with multiple emergency communication options, including voice, text, and one-way video capability, visually confirming cab interior status.

Cab Pads Protective pads that cover the walls (during office moves etc.).

Cab PadsX

Protective pads that cover the walls (during office moves etc.).

Digital Position Indicator Shows passengers what floor that elevator is serving at that time.

Digital Position IndicatorX

Shows passengers what floor that elevator is serving at that time.

Digital Position Indicator - Floors Please input a list of floor numbers that you would like door position indicator to appear.

Digital Position Indicator - FloorsX

Please input a list of floor numbers that you would like door position indicator to appear.

Flashing Fire Sign Special illuminating fire fixture.

Flashing Fire SignX

Special illuminating fire fixture.

Flashing Fire Sign - Floors Please input a list of floor numbers that you would like flashing fire signs to appear.

Flashing Fire Sign - FloorsX

Please input a list of floor numbers that you would like flashing fire signs to appear.

Certificate Frame Frame used to hold the inspection certificate.

Certificate FrameX

Frame used to hold the inspection certificate.

Parking Feature A feature that is set up to send the elevator to a designated floor after it's finished taking it's calls and waits there for the next call.

Parking FeatureX

A feature that is set up to send the elevator to a designated floor after it's finished taking it's calls and waits there for the next call.

Parking Feature - Floors Please input a list of floor numbers that you would like parking features to appear.

Parking Feature - FloorsX

Please input a list of floor numbers that you would like parking features to appear.

Status Panel Fixture that indicates status and location of elevators for one or more cabs.

Status PanelX

Fixture that indicates status and location of elevators for one or more cabs.

Future Cab When a hoistway is being built for a car that is not going to be provided on the current contract, but made available as space for later use.

Future CabX

When a hoistway is being built for a car that is not going to be provided on the current contract, but made available as space for later use.

Future Floor Allows for the additional floor being serviced in the building.

Future FloorX

Allows for the additional floor being serviced in the building.

Hall Lantern Hall fixture that indicates the direction the elevator is going.

Hall LanternX

Hall fixture that indicates the direction the elevator is going.

Hall Lantern - Floors Please input a list of floor numbers that you would like hall lanterns to appear.

Hall Lantern - FloorsX

Please input a list of floor numbers that you would like hall lanterns to appear.

Elevator Management System Advanced building management tool, which allows single point supervision of elevators and escalators within a building.  It presents information using on-screen displays, and accepts control inputs via a standard graphic user interface.

Elevator Management SystemX

Advanced building management tool, which allows single point supervision of elevators and escalators within a building.  It presents information using on-screen displays, and accepts control inputs via a standard graphic user interface.

Button Access Code Restricted access security feature that allows the lock out of specified floors from the inside of the cab.

Button Access CodeX

Restricted access security feature that allows the lock out of specified floors from the inside of the cab.

Access Switch A switch that is required by certain jurisdictions, that allows authorized personnel access to the top of the elevator or the pit.

Access SwitchX

A switch that is required by certain jurisdictions, that allows authorized personnel access to the top of the elevator or the pit.

Access Switch - Floors Please input a list of floor numbers that you would like access switches to appear.

Access Switch - FloorsX

Please input a list of floor numbers that you would like access switches to appear.

Card Reader Provisions Restricted access security feature that uses a card reader (in Cab Operating Panel or Hallway).

Card Reader ProvisionsX

Restricted access security feature that uses a card reader (in Cab Operating Panel or Hallway).

Keyed Switches - Hall Restricted access feature that uses a key to grant access to locked out floors by use of a key in the hall push button fixture.

Keyed Switches - HallX

Restricted access feature that uses a key to grant access to locked out floors by use of a key in the hall push button fixture.

Keyed Switches - Hall - Floors Locked Out Please input a list of floor numbers that you would like keyed switches in the hall push button fixture to appear.

Keyed Switches - Hall - Floors Locked OutX

Please input a list of floor numbers that you would like keyed switches in the hall push button fixture to appear.

Keyed Switches - Cab Restricted access feature that uses a key to grant access to locked out floors by use of a key in the Cab Operating Panel.

Keyed Switches - CabX

Restricted access feature that uses a key to grant access to locked out floors by use of a key in the Cab Operating Panel.

Keyed Switches - Cab - Floors Locked Out Please input a list of floor numbers that you would like keyed switches in the cab operating panel to appear.

Keyed Switches - Cab - Floors Locked OutX

Please input a list of floor numbers that you would like keyed switches in the cab operating panel to appear.

Emergency Options

Emergency Power Provisions to hook up elevator to an emergency power generator.

Emergency PowerX

Provisions to hook up elevator to an emergency power generator.

Rescue Feature Battery lowering device that brings elevator down to lowest level served during a power outage and releases any passengers.

Rescue FeatureX

Battery lowering device that brings elevator down to lowest level served during a power outage and releases any passengers.