Schindler 3300
Schindler 3300
CA, MA, WA, NYC and VT require elevator control rooms, please contact your local Schindler representative for options.
For jurisdictions following ASME A17.1 code prior to 2009, please add 1 additional inch of overhead at 150 FPM.
Capacity CapacityX
The amount of weight an elevator can safely carry.
|
2100 |
2500 |
3000 |
3500 |
---|---|---|---|---|
Speed SpeedX
The top speed the elevator can achieve in feet per minute.
|
100 150 |
100 150 |
100 150 |
100 150 |
Door Type Door TypeX
The number of door panels and the way they open.
|
2SSO |
2SSO SSCO |
2SSO SSCO |
2SSO SSCO |
Number of Stops Max Number of Stops MaxX
Amount of times the elevator can stop on a floor.
|
10 |
10 |
10 |
10 |
Available Entrances Max Available Entrances MaxX
Number of openings the elevator can have.
|
15 |
15 |
15 |
15 |
Travel Height Max Travel Height MaxX
Maximum distance the elevator can travel from the bottom landing to the top most landing served.
|
100 fpm708 150 fpm1181 |
100 fpm708 150 fpm1181 |
100 fpm708 150 fpm1181 |
100 fpm708 150 fpm1181 |
69.3125 |
81.3125 |
81.3125 |
81.3125 |
|
52.875 |
52.875 |
58.875 |
66.875 |
|
Inside Cab Height Inside Cab HeightX
The dimension from the finished floor to the canopy of the cab.
|
93 |
93 |
93 |
93 |
Door Width Door WidthX
The width of the door.
|
36 |
42 |
42 |
42 |
Passenger Max Passenger MaxX
The maximum number of people the elevator can hold.
|
13 |
15 |
18 |
21 |
Door Height Door HeightX
The height of the door.
|
84 |
84 |
84 |
84 |
Hoistway Width Hoistway WidthX
The width of the hoistway.
|
Front OpeningsNo In Seismic Zone?90 Rear OpeningsNo In Seismic Zone?90 Front OpeningsYes In Seismic Zone?92 Rear OpeningsYes In Seismic Zone?92 |
Front OpeningsNo In Seismic Zone?102 Rear OpeningsNo In Seismic Zone?102 Front OpeningsYes In Seismic Zone?104 Rear OpeningsYes In Seismic Zone?104 |
Front OpeningsNo In Seismic Zone?102 Rear OpeningsNo In Seismic Zone?102 Front OpeningsYes In Seismic Zone?104 Rear OpeningsYes In Seismic Zone?104 |
Front OpeningsNo In Seismic Zone?102 Rear OpeningsNo In Seismic Zone?102 Front OpeningsYes In Seismic Zone?104 Rear OpeningsYes In Seismic Zone?104 |
Hoistway Depth Hoistway DepthX
The depth of the hoistway.
|
Front Openings69 Rear Openings77.625 |
Front Openings69 Rear Openings77.625 |
Front Openings75 Rear Openings83.625 |
Front Openings83.0625 Rear Openings91.625 |
Pit Depth Pit DepthX
Depth below the elevator cab's bottom most landing. The pit extends from the level of the lowest landing door down to the floor at the very bottom of the shaft.
|
60 |
60 |
60 |
60 |
Overhead OverheadX
Clear overhead is defined as the lowest point below the roof structure. It's measured to the bottom of the hoist beam. All dimensions are based on 8’ tall cabs. 9’ and 10’ heights are also available. Overhead will increase 12” for each additional foot of cab height.
|
151 |
151 |
151 |
151 |
Notes
- 2SSO doors available with right or left opening.
- Duplex operation available.
- Areas in seismic zone 2 or greater may require up to 3 1/2” more hoistway width. Please contact your Schindler Sales Representative for details and options.
- Clear overhead is defined from the lowest point below any obstruction such as: hoist beam(s), building beams, or roof structure to floor of top landing.
- Where permitted by code, no control closet is required. A 3-phase disconnect must be located in both the hoistway overhead and a location in the building outside of the hoistway. 110v disconnect should be located outside of hoistway. Disconnects are not required to be an elevator-dedicated space. Please confirm with local requirements.
- Travel height max. varies depending on speed (FPM) and capacity (lbs).
- Schindler recommends 8’-6” (2500 – 3500 lbs) and 7’-6” (2100 lbs), providing additional hoistway tolerances.
- Please contact your Schindler Sales Representative for options less than 5’-0.
- Please contact your Schindler Sales Representative for additional hatch options such as diagonal entrances.
- All dimensions are for information only and cannot be used for construction purposes without Schindler confirmation.
- The Schindler 3300 does not require a space-consuming machine room or control closet. However, some jurisdictions still require such space. In those areas please contact your local Schindler sales representative for a room or closet solution.