Schindler 9300AE
Model Number |
60 |
80 |
100 |
---|---|---|---|
Nominal Escalator Width Nominal Escalator WidthX
Overall width of the escalator.
|
32 |
40 |
48 |
Nominal Step Width Nominal Step WidthX
This is the visible width of the steps.
|
24 |
32 |
40 |
Inside to Inside Handrail Inside to Inside HandrailX
Width between the handrails.
|
29.8125 |
37.6875 |
45.5625 |
Centerline to Centerline Handrail Centerline to Centerline HandrailX
Measurement from the center of one handrail to the center of the other handrail.
|
33 |
40.875 |
48.75 |
Outer Deck to Outer Deck Outer Deck to Outer DeckX
Measurement from the edge of one outer deck to the edge of the other outer deck.
|
44.875 |
52.75 |
60.625 |
Wellway Opening Single Unit Wellway Opening Single UnitX
Pit width.
|
47.25 |
55.125 |
63 |
Wellway Opening Two Adjacent Units Wellway Opening Two Adjacent UnitsX
Pit width for two adjacent units.
|
92.5 |
108.25 |
124 |
Pit Length Pit LengthX
Measured from the front to the back of the pit.
|
Two Flat Steps174 Three Flat Steps189 |
Two Flat Steps174 Three Flat Steps189 |
Two Flat Steps174 Three Flat Steps189 |
Maximum Rise Maximum RiseX
Height measured from lower finish floor to upper finish floor.
|
472 |
366 |
315 |
Edge to Edge Support Edge to Edge SupportX
Overall length of wellway.
|
Two Flat StepsH x 1.732 + 15' 6 1/2" Three Flat StepsH x 1.732 + 18' 6 3/4" |
Two Flat StepsH x 1.732 + 15' 6 1/2" Three Flat StepsH x 1.732 + 18' 6 3/4" |
Two Flat StepsH x 1.732 + 15' 6 1/2" Three Flat StepsH x 1.732 + 18' 6 3/4" |
Schindler 9300AE
Model Number |
60 |
80 |
100 |
---|---|---|---|
Nominal Escalator Width Nominal Escalator WidthX
Overall width of the escalator.
|
32 |
40 |
48 |
Nominal Step Width Nominal Step WidthX
This is the visible width of the steps.
|
24 |
32 |
40 |
Inside to Inside Handrail Inside to Inside HandrailX
Width between the handrails.
|
29.8125 |
37.6875 |
45.5625 |
Centerline to Centerline Handrail Centerline to Centerline HandrailX
Measurement from the center of one handrail to the center of the other handrail.
|
33 |
40.875 |
48.75 |
Outer Deck to Outer Deck Outer Deck to Outer DeckX
Measurement from the edge of one outer deck to the edge of the other outer deck.
|
44.875 |
52.75 |
60.625 |
Wellway Opening Single Unit Wellway Opening Single UnitX
Pit width.
|
47.25 |
55.125 |
63 |
Wellway Opening Two Adjacent Units Wellway Opening Two Adjacent UnitsX
Pit width for two adjacent units.
|
92.5 |
108.25 |
124 |
Pit Length Pit LengthX
Measured from the front to the back of the pit.
|
Two Flat Steps174 Three Flat Steps189 |
Two Flat Steps174 Three Flat Steps189 |
Two Flat Steps174 Three Flat Steps189 |
Maximum Rise Maximum RiseX
Height measured from lower finish floor to upper finish floor.
|
669.25 |
590.5 |
511.75 |
Edge to Edge Support Edge to Edge SupportX
Overall length of wellway.
|
Two Flat StepsH x 1.732 + 15' 6 1/2" Three Flat StepsH x 1.732 + 18' 6 3/4" |
Two Flat StepsH x 1.732 + 15' 6 1/2" Three Flat StepsH x 1.732 + 18' 6 3/4" |
Two Flat StepsH x 1.732 + 15' 6 1/2" Three Flat StepsH x 1.732 + 18' 6 3/4" |
Notes
- Dimensions are for applications in the United States. Some dimensions change for seismic applications. For specific requirements in Canada, please consult your local sales office. Schindler Elevator Corporation reserves the right to change dimensions. Maximum rises indicated cannot be reached without use of deep truss or intermediate supports. Please contact your local Schindler sales representative for details. Seismic conditions will increase the pit length, edge to edge of supports, and will require intermediate support or deep truss earlier. Contact your local Schindler sales representative if you are in a seismic area.
- In case of outdoor installations, a water drain should be provided.
- Higher rises may be available; please contact your local sales representative.